NBS Specifications – Section L20–540

On completion you are able to print the specification.

London Wall Type RG Example NBS Specification

Manufacturer:

London Wall Design Ltd

Address:

63 Barwell Business Park
Leatherhead Road
Chessington
Surrey
KT9 2NY

Contact details:

Tel: +44 (0)20 8391 8750
Fax: +44 (0)20 8391 8751
E mail: sales@londonwall.co.uk
Web: www.londonwall.co.uk

Product Description:

Type RG top hung frameless glass sliding partition

Glass Thickness:

10/12mm thick clear toughened or laminated, single or double glazed up to 52mm

Frame:

Aluminium, thermally insulated – 77mm/106mm/185mm wide x 75mm deep

Vertical Joints:

Vertical edge of panel closing through self locating 25mm deep male / female profiles complete with seals

Operable seals:

Removable crank handle or electronics operates internal worm screw gear which extends / contracts the retractable top bottom seals concurrently. This rapid action mechanism allows the rubber clad aluminium seals to travel up to 30mm out of the panel (or more if required), and provide a firm contact of 15KN of pressure with floor and ceiling track surfaces

Sound Insulation:

Up to Rw 39dB (laboratory tested)

Height Adjustment:

Each panel to be individually adjustable in height to take up any discrepancy in floor levels

Panel Weight:

Maximum approximately 50Kg/m² dependant on glass required

Ceiling track:

Aluminium or steel powder coated RAL 9010 white as standard or to clients’ colour specification

Support detail:

System to be supported from suitable load bearing structure above as per manufacturers' & specialist engineers’ recommendations. Support to be fixed within a ceiling void of mm and include a plasterboard acoustic baffle to match the sound insulation rating required

Opening dimensions:

mm wide x mm high

Options

  • Glazing bars
  • Full height and inset pass doors are available
  • Can interconnect with our type 100 system if required for high levels of visual and sound performance
  • For internal or external use

NB: options include special panel, finishes pass door panels, layout configurations glazing requirements, etc